5100
SERIES FAN FORCED SUSPENDED
ELECTRIC UNIT HEATERS |
3.3 KW
THROUGH 50 KW SUSPENDED FAN FORCED UNIT HEATERS AVAILABLE IN 1 OR 3 PHASE
FOR ALL STANDARD VOLTAGES FROM 208V TO 480V THAT CAN BE MOUNTED TO PROVIDE
HORIZONTAL OR VERTICAL DISCHARGE. |
|
|
|
 |
|
Horizontal
or Vertical Discharge Airflow |
|
Heavy gauge welded steel cabinet with powder-coated finish and control compartment
housing a master terminal board with a hinged and latched access
door, simplifying
wiring, installation and maintenance
Copper clad steel sheath element with continuously brazed steel fins
formed to allow
side draw through airflow
Units equipped with automatic resetting type limit control.
Adjustable louvers for directional air flow control
Units with model numbers ending in CA are factory wired for low voltage
controls
Shipped fully assembled
Made in U.S.A. |
Horizontal
Discharge |
|
|
|
|
|
|
|
|
|
 |
|
Taskmaster
Dimensions |
|
|
|
KW
RATING |
DIMENSIONS
(inches) |
H |
W |
D |
3.3
- 5.0 |
17
3/4 |
14
15/32 |
6
1/2 |
7.5
- 10.0 |
24
5/16 |
21
1/2 |
6
1/2 |
15.0
- 20.0 |
28
11/16 |
21
1/2 |
6
1/2 |
25.0
- 50.0 |
34 |
29
1/4 |
10
1/16 |
|
|
|
|
|
|
|
|
|
FAN
and MOTOR: |
|
TEMPERATURE
CONTROLS: |
Totally
enclosed, 1-speed, 1-phase, permanently
lubricated, thermally protected motors with unit
bearings on 3 KW - 20 KW models. Totally
enclosed, 2-speed, 1-phase, permanently lubricated,
thermally protected motors with sleeve bearings
on 25 KW - 50 KW models. All motors mounted
with rubber insulators to minimize vibration & noise.
Fan override purges unit of residual heat at shutdown. |
|
Optional low voltage
and line voltage thermostats
available with an adjustable temperature range of
40°F to 110°F. Units with model numbers ending
in CA1 are factory wired for low voltage controls.
25 KW through 50 KW units are designed for two
stage heating operation. |
|
|
|
INSTALLATION: |
|
Unit
Heaters can be mounted for horizontal or vertical discharge. |
|
|
LOUVER
ASSEMBLY: |
|
Louvers
are individually adjustable for directional control
of air flow up to 15° from straight horizontal. Optional
diffusers available for down flow (vertical discharge) applications. |
|
|
|
|
FIELD
INSTALLED OPTIONS: |
|
In-unit or wall mounted temperature control thermo-
stats low or line voltage.
Summer fan switch to operate the fan only.
Power disconnect switch.
Heat stratification thermostat. |
|
|
|
|
 |
|
Order
Online, by Phone, or by E-Mail |
|
|
|
~ Add
items to your online shopping cart ~
Click a Price of the item you wish to purchase. |
|
|
PRICING |
MODEL
NO. |
KW |
VOLTS |
PHASE |
AMPS |
CONTROL
VOLTAGE |
PRICE
EACH |
HF2B5105N |
5 |
240 |
1 / 3 |
20.8 / 18.1 |
240 |
|
3.7 |
208 |
12.1 / 10.4 |
208 |
|
HF2B5107CA1L |
7.5 |
240 |
27.1 / 31.3 |
24 |
|
5.6 |
208 |
31.3 / 27.1 |
|
HF2B5110CA1L |
10 |
240 |
41.2 / 24.0 |
|
7.5 |
208 |
36.1 / 20.8 |
|
P3P5105CA1N |
5 |
480 |
3 |
6.1 |
|
P3P5107CA1N |
7.5 |
9.1 |
|
P3P5110CA1N |
10 |
12.1 |
|
|
|
|
HEATER
ACCESSORIES PRICING |
|
MODEL
NO. |
DESCRIPTION |
MODEL
SIZE / TYPE |
WT.
(LBS) |
PRICE
EACH |
A5105 |
Mounting
Brackets |
3.3
KW to 5.0 KW |
9 |
|
A5120 |
7.5
KW to 20.0 KW |
13 |
|
T5100 |
Field
Installed
Thermostat |
SPST
Line Voltage (Built-In) Stat |
|
T5102 |
DPST
Line Voltage (Built-In) Stat |
|
|
|
|
Installing
the Taskmaster Series |
|
DETERMINING
HEATER REQUIREMENTS
Calculate the heating loads using the NEMA handbook or ASHRAE guide. Then
determine the quantity and size of
unit heaters to be used. To maintain uniform heat and reduce stratified
air, it is recommended that the total CFM of
the units turn the air over approximately 3 times per hour. In instances
where a large group of people are located
and normally in the same area, use a large number of lower KW unit heaters.
In warehouse areas or storage rooms
where heat distribution and constant temperatures are less important, use
fewer heaters of higher capacity. |
|
HORIZONTAL
MOUNT
Small rooms can be heated by one unit heater. Where two walls are exposed,
heaters should be mounted as shown
in Figure A. In larger rooms, units should he located so their air streams
wipe exposed walls without blowing at them.
Units should be located so that the air stream of one supports that of another
thus setting up a circulatory air
movement shown in Figure B. (Distance between units to be approximately
1-1/2 times published air throw.)
Units should not be mounted horizontally in areas having ceiling heights
in excess of 15-18 ft. |
|
VERTICAL
MOUNT
Units should be mounted vertically in high bay areas, or where heater location
would not interfere with plant operation
or traffic, Heaters should be situated to provide free air circulation.
Size and selection of units should be based on
recommended mounting height. Optional diffusers may best be employed to
reduce high air velocity and at the same
time disperse heated air in a uniform pattern. When unit heaters are used
to combat cold air inrush from opened
loading dock doors, one or more units should be arranged to blow warm air
across opening (Figure C). |
|
DUAL
MOUNTING
Where square footage is large and comfort essential, both horizontal and
vertical installations may best serve your
requirements as Figure D demonstrates. |
|
Note: Products in this section with factory installed controls are subject to
100% cancellation/restocking charges. |
|
 |
|
Fan Forced Suspended Electric
Unit Heaters, Electric Heaters, Suspended Heaters, Radiant Forced Heater,
Electric Heater, Space
Heaters, Horizontal or Vertical Discharge, Ceramic Heaters, and Fan Heaters
from your source for material handling equipment. |
Back
to Product Category |
 |
|