ENGINEERED
STEEL PRODUCTS |
| Priced
Full Line Products Catalog |
PO
Box 72659 Providence, RI 02907
Toll free:(800) 421-0314 In RI:(401) 421-0314 Fax:(401) 421-5679 |
 |
|
|
 |
Back
to Product Category
|
HEATED
AIR CURTAINS
|
|
|
|
|
|
|
MODEL
C - CH - CHS ELECTRIC HEATED SERIES
|
|
|
|
|
|
 |
|
|
|
|
*
CLIMATE CONTROL
*
INSECT CONTROL
*
ENERGY CONTROL
|
|
|
|
|
|
|
|
|
|
ADVANTAGES
Keeps insects, dust, dirt, and fumes out.
For use over freezer and cooler doors to reduce humidity
and prevent loss of cold air.
Doors may be left open eliminating the nuisance of
opening and closing automatic and manual doors.
Reduce air conditioning costs.
Open doors conductive to attracting customers.
Less risk of accidents yet speeds up customer or
personnel traffic.
Keep premises clean and sanitary. |
HIGHEST
QUALITY * SUPERIOR DESIGN
Easiest to install and maintain
5 Year guarantee on all parts (Unheated models)
Immediate shipment
Over 400,000 units installed
Made in the U.S.A. for 35 year. |
|
|
|
|
|
|
|
|
|
|
|
 |
|
|
|
|
|
|
|
|
|
|
FOR
USE IN ALL SEASONS |
| FOR
USE OVER ENTRANCE DOORS IN |
|
|
1)
WITH HEATER AND FAN ON |
Shopping
Plazas * Supermarkets * Restaurants * Drug
Stores * Department Stores * Office Buildings * Hotels
* Motor Inns * Hospitals and Convalescent Homes |
|
|
|
over
entrance doors as protection against cold
wintry drafts entering indoor heated areas.
Contributes warmth to existing heating system. |
|
|
|
|
QUALITY
ASSURANCE DESIGN AND
CONSTRUCTION |
|
|
|
|
|
2)
WITH FAN ON ONLY |
|
|
in
warm weather to prevent loss of air conditioning
and provide an effective barrier against insects,
dust and fumes. |
Architects and engineers are justifiably concerned about
the products they specify. The products must be reliable,
economical, efficient and last for a considerable length of
time. That is why the architect or engineer who is familiar
with air curtains will choose these air curtain over all others. |
|
|
|
|
|
|
|
|
Heated
air curtain must be mounted on inside
of building |
|
|
|
|
|
|
 |
|
Note:
Model number designates length of unit in inches VOLTAGE
- PHASE - WATTS must be specified when
ordering. All models listed below have high impact PolyMars®
Housing, Color: White. Indoor installation
MANDATORY on heated models. |
|
|
|
|
PRICES
FOR THE C AND CH SERIES MODELS (HEATED)
|
|
|
|
| Heated
Units with One 1/2 Horsepower Motor |
|
Height:
15 1/2" Depth: 12 3/4"
|
|
Single Phase Units |
|
Voltage |
6,000 Watts |
9,000 Watts |
12,000 Watts |
|
20,500 Btu/hr |
30,700 Btu/hr |
41,000 Btu/hr |
|
208 |
31 Amps |
46 Amps |
60 Amps |
|
240 |
28 Amps |
40 Amps |
53 Amps |
|
Model |
Price |
Price |
Price |
|
E38C or CH |
$1,622.50 |
$1,666.50 |
$1,721.50 |
|
E42C or CH |
$1,655.50 |
$1,694.00 |
$1,743.50 |
|
E48C or CH |
$1,683.00 |
$1,727.00 |
$1,765.50 |
|
E60C |
$1,727.00 |
$1,776.50 |
$1,826.00 |
|
|
|
Three Phase Units |
|
Voltage |
8,000 Watts |
12,000 Watts |
16,000 Watts |
|
27,300 Btu/hr |
41,000 Btu/hr |
54,600 Btu/hr |
|
208 |
23 Amps |
35 Amps |
46 Amps |
|
240 |
21 Amps |
30 Amps |
40 Amps |
|
480 |
10 Amps |
15 Amps |
20 Amps |
|
Model |
Price |
Price |
Price |
|
E38C or CH |
$1,705.00 |
$1,732.50 |
$1,782.00 |
|
E42C or CH |
$1,727.00 |
$1,765.50 |
$1,798.50 |
|
E48C or CH |
$1,754.50 |
$1,787.50 |
$1,848.00 |
|
E60C |
$1,776.50 |
$1,837.00 |
$1,881.00 |
|
|
|
|
|
|
| 5,
6 & 8 ft Heated Units with Two 1/2 Horsepower Motor |
5
& 6 ft. Height: 15 1/2" Depth 12 3/4"/8 ft Height:
18" Depth: 15"
|
|
|
|
Single Phase Units |
|
Voltage |
12,000 Watts |
18,000 Watts |
|
41,000 Btu/hr |
61,400 Btu/hr |
|
208 |
62 Amps |
92 Amps |
|
240 |
56 Amps |
80 Amps |
|
Model |
Price |
Price |
|
E60C-2 or CH |
$2,947.05 |
$3,024.75 |
|
E72C-2 or CH |
$2,997.00 |
$3,063.60 |
|
E96C-2 or CH |
$3,318.90 |
$3,385.50 |
|
|
|
|
Three Phase Units |
|
Voltage |
16,000 Watts |
24,000 Watts |
32,000 Watts |
|
54,600 Btu/hr |
82,000 Btu/hr |
109,200 Btu/hr |
|
208 |
46 Amps |
70 Amps |
92 Amps |
|
240 |
42 Amps |
60 Amps |
80 Amps |
|
480 |
20 Amps |
30 Amps |
40 Amps |
|
Model |
Price |
Price |
Price |
|
E60C-2 or CH |
$3,058.00 |
$3,146.00 |
$3,239.50 |
|
E72C-2 or CH |
$3,107.50 |
$3,195.50 |
$3,289.00 |
|
E96C-2 or CH |
$3,432.00 |
$3,503.50 |
$3,602.50 |
|
|
|
|
|
|
|
|
| Heated
Units with One 1 Horsepower Motor |
|
Height:
18" Depth: 15"
|
|
Single Phase Units |
|
Voltage |
6,000 Watts |
9,000 Watts |
12,000 Watts |
|
20,500 Btu/hr |
30,700 Btu/hr |
41,000 Btu/hr |
|
208 |
37 Amps |
52 Amps |
66 Amps |
|
240 |
34 Amps |
46 Amps |
59 Amps |
|
Model |
Price |
Price |
Price |
|
E42CHS |
$2,098.25 |
$2,130.95 |
$2,185.45 |
|
E48CHS |
$2,141.85 |
$2,185.45 |
$2,234.50 |
|
E60CHS |
$2,196.35 |
$2,234.50 |
$2,250.85 |
|
|
|
Three Phase Units |
|
Voltage |
8,000 Watts |
12,000 Watts |
16,000 Watts |
|
27,300 Btu/hr |
41,000 Btu/hr |
54,600 Btu/hr |
|
208 |
26 Amps |
38 Amps |
49 Amps |
|
240 |
24 Amps |
33 Amps |
43 Amps |
|
480 |
12 Amps |
17 Amps |
22 Amps |
|
Model |
Price |
Price |
Price |
|
E42CHS |
$2,183.50 |
$2,227.50 |
$2,271.50 |
|
E48CHS |
$2,244.00 |
$2,271.50 |
$2,321.00 |
|
E60CHS |
$2,288.00 |
$2,321.00 |
$2,376.00 |
|
|
|
|
|
|
| 8
ft. Heated Units with Two 1 Horsepower Motors |
|
Height:
18" Depth: 15" |
|
Single Phase Units |
|
Voltage |
12,000 Watts |
18,000 Watts |
|
41,000 Btu/hr |
61,400 Btu/hr |
|
208 |
74 Amps |
104 Amps |
|
240 |
68 Amps |
92 Amps |
|
Model |
Price |
Price |
|
E96CHS-2 |
$4,118.10 |
$4,184.70 |
|
|
|
Three Phase Units |
|
Voltage |
16,000 Watts |
24,000 Watts |
32,000 Watts |
|
54,600 Btu/hr |
82,000 Btu/hr |
109,200 Btu/hr |
|
208 |
52 Amps |
76 Amps |
98 Amps |
|
240 |
48 Amps |
66 Amps |
86 Amps |
|
480 |
24 Amps |
34 Amps |
44 Amps |
|
Model |
Price |
Price |
Price |
|
E96CHS-2 |
$4,224.00 |
$4,312.00 |
$4,405.50 |
|
|
|
|
|
|
|
 |
|
|
|
|
For performance specifications refer to C models chart above.
Model Number Designates Length of Housing. Add 4"
on side for control box plus 12" clearance for panel door
opening. |
|
|
|
|
HEATED UNIT SELECTION GUIDE
|
Door Widths
Up To |
Door Heights
Up To |
Use Model
Number |
1750 RPM
Motor H.P. |
Max FPM
at Nozzle |
Max CFM
at Nozzle |
Wgt. Lbs. |
|
3 ft 2 in |
8 ft |
E38C |
1/2 |
2150 |
1700 |
70 |
|
3 1/2 ft |
8 ft |
E42C |
1/2 |
1950 |
1700 |
75 |
|
4 ft |
8 ft |
E48C |
1/2 |
1700 |
1700 |
80 |
|
5 ft |
8 ft |
E60C |
1/2 |
2040 |
2550 |
85 |
|
5 ft |
8 ft |
E60C-2 |
Two 1/2 |
2720 |
3400 |
125 |
|
6 ft |
8 ft |
E72-C |
Two 1/2 |
2275 |
3400 |
140 |
|
8 ft |
8 ft |
E96-C |
Two 1/2 |
1700 |
3400 |
160 |
|
Note: For 10 foot high door openings use heated
CH models (EXAMPLE: E38C IS E38CH) |
|
CHS MODELS |
|
3 1/2 ft |
12 ft |
E42CHS |
1 |
4600 |
4000 |
110 |
|
4 ft |
12 ft |
E48CHS |
1 |
4000 |
4000 |
115 |
|
5 ft |
12 ft |
E60CHS |
1 |
3200 |
4000 |
125 |
|
8 ft |
12 ft |
E96CHS |
Two 1 |
4000 |
8000 |
215 |
|
| Note:
For wider doorways, units can be mounted in multiple and arranged
for single thermostat control. Contact us. |
|
|
|
Standard
Equipment: Prewired control box ready for power connection.
Wall mounted 24 Volt thermostat with
remote "Heat/Off/Fan only" switch.
Note: Control box mounted on right hand side unless otherwise
specified. |
|
| Optional
Modifications for Heated Series |
|
Descriptions |
Price |
|
TZ6112 Door Limit Switch (Combi Style - both a roller
and plunger all in one) 20 AMP Shipped Loose |
$66.00 |
|
Adjustable Time Delay - adjustable from 1-17 minutes -
Used for high traffic areas |
$192.50 |
|
Master Slave Control with Single Thermostat - Used to
control multiple units side by side |
$99.00 per slave |
|
Hi/Lo heat control with switch located on control box
(Available in three phase only) |
$154.00 |
|
Two speed motor with Hi/Lo switch located on control box |
|
(NOTE: 480 volt air curtain, if specified with two motor,
separate 120 or 240 single phase motor service is required) |
$154.00 |
|
Digital Thermostat |
$110.00 |
|
Nozzle Extensions |
Consult us |
|
SPECIFIC NOTES: |
|
Voltage availability 115, 208, 230/1/60 & 208, 230,
460, 575/3/60 (50/60 Hz) & 380/3/50 (remaining product
line) |
|
Additional Charge for 1/2 HP Three Phase Motors, 277v
and 575v motors …………. Add per motor |
$82.50 |
All 3 Phase Motors or Single Phase combined motors greater
than 1 HP or over 250 VAC or greater then 20 Amps require
a motor control panel whenever a door limit switch is
used to start and stop the air curtain. A door limit switch
may be
used to direct |
All Electric Heated Units include a control panel (on
right-handside of unit) and remote 24 volt thermostat
with
"Heat/off/fan only" switch. For remote control
panels …………………….. Add |
$165.00 |
|
|
| EC
- ECH - ECHS COMMERCIAL ELECTRIC HEATED MODELS |
 |
 |
|
Heated
Air Curtains, Air Curtain, Air Curtain Door, Air Curtain Heater,
Air Curtains, Air Doors, Door Air Curtains, Heat Curtains,
Mars Air Curtain, Mars Air Door, Warm Air Curtains, and Insect
Barrier from your source for material handling equipment. |
Back
to Product Category |
 |
|