ENGINEERED
STEEL PRODUCTS |
| Priced
Full Line Products Catalog |
PO
Box 72659 Providence, RI 02907
Toll free:(800) 421-0314 In RI:(401) 421-0314 Fax:(401)
421-5679 |
 |
|
|
 |
Back
to Product Category
|
LoPro
Commercial Series Air Curtains
|
|
The
Most Cost-effective Environmental and Sanitation Barrier Youll
Never See
|
|
 |
|
|
|
| The
Most Cost-Effective Environmental and Sanitation Barrier You'll
Never See |
|
|
|
| AIR
CURTAIN BENEFITS |
DOOR
WIDTHS |
Reduces Energy Costs And Consumption
Creates Effective Environmental Separation
Maintains Interior Building Temperatures
Provides Low Operational Costs
Minimizes Dirt, Dust, And Fumes
Prevents Flying Insects From Intruding
Offers An Unobstructed View, Enhancing Safety |
25"
to 144" |
| DOOR
HEIGHTS |
Environmental
Separation up to 8'
Flying Insect Control up to 7' |
| HEATING
OPTIONS |
| Electric
and Steam/Hot Water |
| AVAILABLE
IN FOUR COLORS |
LOPRO
COMMERCIAL AIR CURTAINS
SERIES FEATURES |
|
 |
Aesthetically Pleasing Low Profile 8" Design
Low Noise Level For Quiet Operation
Easy To Install
Low Maintenance
NSF Models Available
(See NSF sheet below for complete specifications.)
|
|
|
|
| Optional
Colors: |
Obsidian
Black - Standard Production Color
Pearl White - $20.00 per
linear foot (indicate PW after voltage code)
Titanium Silver - $20.00
per linear foot (indicate TS after voltage code)
Spartan Bronze - $20.00
per linear foot (indicate SB after voltage code)
Stainless Steel - $100.00
per linear foot (indicate SS after voltage code) |
|
|
|
 |
|
|
PRICING
|
|
Model Number |
Width
of Door |
Door
Height |
Motor HP
@ 1550
RPM** |
Fla Single Phase |
dBA
Measured
10 ft. from Nozzle |
Weight
(lbs.) |
Max.
FPM**
at Nozzle |
Max.
CFM**
at Nozzle |
Price |
|
115 V |
208V/230V |
|
LPV30/LPN30-1U* |
30" |
7' - 8' |
1 @ 1/6 |
2.4 |
1.2 |
49 |
28 |
1800 |
750 |
$655 |
|
LPV36/LPN36-1U* |
36" |
7' - 8' |
1 @ 1/6 |
2.4 |
1.2 |
49 |
35 |
1800 |
900 |
$699 |
|
LPV42/LPN42-1U* |
42" |
7' - 8' |
1 @ 1/6 |
2.4 |
1.2 |
50 |
38 |
1800 |
1050 |
$733 |
|
LPV48/LPN48-1U* |
48" |
7' - 8' |
1 @ 1/6 |
2.4 |
1.2 |
52 |
42 |
1800 |
1200 |
$760 |
|
LPV60/LPN60-1U* |
60" |
7' - 8' |
1 @ 1/6 |
2.6 |
1.4/1.4 |
53 |
51 |
1800 |
1500 |
$794 |
|
LPV72/LPN72-1U* |
72" |
7' - 8' |
1 @ 1/6 |
2.6 |
1.4/1.4 |
53 |
61 |
1800 |
1800 |
$1,005 |
|
LPV84/LPN84-2U* |
84" |
7' - 8' |
2 @1/6 |
4.8 |
2.4/2.4 |
53 |
79 |
1800 |
2100 |
$1,465 |
|
LPV96/LPN96-2U* |
96" |
7' - 8' |
2 @1/6 |
4.8 |
2.4/2.4 |
53 |
87 |
1800 |
2400 |
$1,521 |
|
LPV108/LPN108-2U* |
108" |
7' - 8' |
2 @1/6 |
5.0 |
2.6/2.6 |
54 |
96 |
1800 |
2700 |
$1,576 |
|
LPV120/LPN120-2U* |
120" |
7' - 8' |
2 @1/6 |
5.2 |
2.8/2.8 |
54 |
105 |
1800 |
3000 |
$1,632 |
|
LPV144/LPN144-2U* |
144" |
7' - 8' |
2 @1/6 |
5.2 |
2.8/2.8 |
54 |
125 |
1800 |
3600 |
$2,009 |
|
| *
LPN units are ETL Sanitation (NSF/ANSI 37) approved. Variable
speed not available. |
|
Add Code for required voltage from chart below |
| **-17%
Reduction in Performance on units with 50 Hz. |
|
|
|
 |
|
 |
|
|
LOPRO
ACCESSORIES - UNHEATED
|
|
LEVEL 1 CONTROL PACKAGE - Low Traffic Doors |
|
LINE VOLTAGE |
|
Part # |
Package |
Price |
|
99-014 |
Door Limit Switch - Both Plunger & Roller all-in-one
20 amps, up to 250v, up 1 HP |
$66.60 |
|
24 VOLT CONTROL |
|
|
|
Part # |
Package |
Price |
|
J0023 |
Magnetic Reed Switch Control (115v) up to 1 HP Magnetic
reed switch with controller (RIB) |
$144.30 |
|
J0024 |
Magnetic Reed Switch Control (208/230v) up to 1 HP Magnetic
reed switch with controller (RIB) |
$144.30 |
|
99-018 |
Additional Magnetic Reed Switch (only) Used in conjunction
with J0023 or J0024 for double doors |
$33.30 |
|
LEVEL 2 CONTROL PACKAGE - High Traffic Doors (RECOMMENDED) |
|
24 VOLT CONTROL |
|
Part # |
Package |
Price |
|
J0021 |
Magnetic Reed Switch, Adj. Time Delay Control (115v) up
to 1 HP Magnetic reed switch,
controller, & adjustable time delay (6 sec - 20 min)
(RIB) |
$177.60 |
|
J0022 |
Magnetic Reed Switch, Adj. Time Delay Control (208/230v)
up to 1 HP Magnetic reed switch,
controller, & adjustable time delay (6 sec - 20 min)
(RIB) |
$177.60 |
|
99-018 |
Additional Magnetic Reed Switch (only) Used in conjunction
with J0021 or J0022 for double doors |
$33.30 |
|
J0028 |
Door Limit Switch , Adj. Time Delay Control (115v) up
1 HP Door limit switch, controller,
& adjustable time delay (6 sec-20 min) (RIB) |
$222.00 |
|
J0029 |
Door Limit Switch , Adj. Time Delay Control (208/230v)
up 1 HP Door limit switch, controller,
& adjustable time delay (6 sec-20 min) (RIB) |
$222.00 |
|
MOUNTING BRACKETS/INSTALLATION KITS |
|
Part # |
Mounting Bracket/Installation Kit |
Price |
|
99-061 |
Easy install Top Mounting Kit for NSF ANSI 37 Certified |
$49.95 |
|
98-061 |
Easy install Top Mounting Kit |
$49.95 |
|
J0030 |
Tandem Mounting Kit: Used when units are mounted side
by side |
$55.50 |
|
J0031 |
Walk-in Installation Kit 115v: Magnetic reed switch, controller,
and nylon bolt |
$166.50 |
|
J0032 |
Walk-in Installation Kit 208-230v: Magnetic reed switch,
controller, and nylon bolt |
$166.50 |
|
FILTERS |
|
Part No. |
Filters |
Price |
|
FIL-(size) |
Aluminum Mesh (1/4") - indicate size in inches |
$9/ft. |
|
|
|
LOPRO
(LPV) VARIABLE SPEED COMMERCIAL UNHEATED MODELS
|
 |
|
|
|
NOTES: |
|
1.
This product is designed to meet the
National Electric Code (NEC) and is ETL
Listed for the US and Canada. |
|
2.
Continuous duty, direct drive, variable speed,
double shaft motors with automatic thermal
overload protection. Overload protects
motor from burnout, minimizing maintenance
costs. Motor connected with an 8' cord, three
conductor cord and plug. |
|
3.
Blower wheels are rust proof and dynamically
balanced to provide quiet operation, while
maintaining high air velocity. |
|
4.
Low profile appearance. Overall height is 8"
and overall depth is 10 3/4". |
|
5.
Air directional vanes, with 40° sweep front to
back, compensates for drafts. |
|
6.
Mounted adjustable speed controller knob
allows air velocity to meet a wide range
of field
conditions. Units greater than 72" are
double
units joined with a 2" mounting bracket
located in the center, field installed. The
speed controller will be located on the right
hand unit and controls both units. |
|
|
|
|
|
| *Bearing
Cap Adds 1/2" to unit length |
|
 |
|
|
7.
All units have a self contained one piece
cabinet, fire retardant and corrosion proof
point
lock metal, double protected with Obsidian
Black rust preventative electrostatic
powdercoating . |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
8.
Normally closed door limit switch(es) is
optional and field installed. Switch to be
mounted so the air curtain turns on
as the door begins to open. |
|
|
LOPRO
(LPN) NSF COMMERCIAL UNHEATED MODELS
|
 |
|
|
|
NOTES: |
|
1.
This product is designed to meet the
National Electric Code (NEC) and is ETL
Listed for the US and Canada. |
|
2.
Continuous duty, direct drive, variable speed,
double shaft motors with automatic thermal
overload protection. Overload protects
motor from burnout, minimizing maintenance
costs. Motor connected with an 8' cord, three
conductor cord and plug. |
|
3.
Blower wheels are rust proof and dynamically
balanced to provide quiet operation, while
maintaining high air velocity. |
|
4.
Low profile appearance. Overall height is 8"
and overall depth is 10 3/4". |
|
5.
Air directional vanes, with 40° sweep front to
back, compensates for drafts. |
|
6.
Countertop or concession applications are
denoted with an -F at the end of the model
numbers and supplied with washable
aluminum filters. LPN25, LPN28 & LPN30
include the washable aluminum filters as
standard. |
|
|
|
|
|
|
|
| *Bearing
Cap Adds 1/2" to unit length |
|
|
|
|
|
7.
All units have a self contained one piece
cabinet, fire retardant and corrosion proof
point lock metal, double protected with
Obsidian Black rust preventative electrostatic
powder coating . Units greater than 72"
are
double units joined with a 2" mounting
bracket located in the center, field installed.
|
|
 |
|
 |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
8.
Normally closed door limit switch(Es) is
optional and field installed. Switch to be
mounted so the air curtain turns on
as the door begins to open. |
|
|
Model No. |
Unit Length
(A) |
|
LPV30/LPN30 |
30" |
|
LPV36/LPN36 |
36" |
|
LPV42/LPN42 |
42" |
|
LPV48/LPN48 |
48" |
|
LPV60/LPN60 |
60" |
|
LPV72/LPN72 |
72" |
|
LPV84-2/LPN84-2 |
86" |
|
LPV96-2/LPN96-2 |
98" |
|
LPV108-2/LPN108-2 |
110" |
|
LPV120-2/LPN120-2 |
122" |
|
LPV144-2/LPN144-2 |
146" |
|
|
|
|
TYPICAL
INSTALLATION
|
|
|
1-
lnstall Mounting plate(s) using the pre-drilled
holes. |
|
|
2
- Securely attach cabinet to mounting plate
using tabs as guides, when fully
inserted
secure with (2) #10 Tek Screws.
"CAUTION":
Unit to be mounted with
the lowest moving part at least
7 Feet above
floor or grade level. |
|
|
3
- lnstall optional door limit switch(Es) to door
header. (8) |
|
|
4
- Plug in unit using the 3-wire cord / plug
supplied. |
|
|
|
|
|
|
|
|
|
INSTALLATION
INSTRUCTION FOR UNHEATED LOW PROFILE
(LPV & LPN SERIES) AIR CURTAIN
|
|
READ
INSTRUCTION BEFORE REMOVING FROM CARTON
|
|
|
|
| INSTALLATION
INSTRUCTIONS: |
|
PRELIMINARY |
1.
Carefully remove the unit from the box. Loosen the
screws from the intake screen and remove
the intake
screen. |
|
|
|
1.
Center the air curtain mounting bracket on solid wall
over doorway. |
|
|
|
2.
Spot holes through 5/16" mounting holes in bracket.
If necessary, drill additional holes in bracket
to match
wall stud or any other mounting bars spacing
supplied
in the field. |
|
|
2.
Gently remove all packaging materials, hardware and
other accessories from interior of unit prior
to operating. |
|
|
|
3.
Remove the Tek Screws from the wall mounting plate
and remove the mounting plate from the unit. |
|
|
|
|
3.
Securely fasten mounting bracket with the proper
fastener and set air curtain in key hole
slots provided. |
|
|
4.
Install the mounting plate above the opening. The
lowest point of the unit must be at least
1" above any
obstructions, ie.. doors and/or door closers,
etc...
when the unit is installed. |
|
|
|
|
4.
Adjust air directional vanes approximately 15°
towards the wind load. |
|
|
|
5.
Connect to proper voltage and phase. |
|
|
5.
Align the tabs on the rear of the unit with the slots
provided on the wall mounting plate (see
drawing
below). The bottom flange on the unit must
also drop
in the bottom channel of the wall mounting
plate.
Replace the Tek Screws to secure the unit in plate. |
|
|
NOTE:
LoPro air curtains are not recommended for
heavy insect control. |
|
|
|
ADJUSTMENTS |
|
1.
Pull air directional vanes in air discharge nozzle to
proper position with air flow slanted slightly
outward
around 15°. |
NOTE:
If the holes provided on the bottom of the unit
and the bottom of the wall mounting plate do not align,
remove the unit and re-install The holes on the bottom
channel of the wall mounted plate must be on the bottom. |
|
|
2.
Set air velocity control louvers so that the air stream
just reaches the floor to prevent turbulent
mixing of
inside and outside air. |
|
|
6.
The discharge must be free and clear of any
obstacles for optimum performance. |
|
|
3.
The unit is to be installed such that the airflow is
unobstructed. |
|
|
7.
All wires must be connected internal of the unit and
some knockouts are provided. However, it
may be
necessary to create your own knockout, as
required. |
|
|
|
NOTE:
MODEL NUMBER DESIGNATES THE
LENGTH OF THE UNIT IN INCHES. |
|
|
|
|
|
| 8.
The unit must be wired per NEC and local codes. |
|
|
|
|
|
|
 |
|
|
|
|
|
 |
|
Model
No. |
Voltage |
Model
Length |
Mounting Hole
Locations |
|
A** |
B |
C |
|
LPV25* |
115/208/230V |
25" |
- |
12.5" |
|
LPV28* |
115/208/230V |
28" |
- |
14" |
|
LPV30* |
115/208/230V |
30" |
- |
15" |
|
LPV36* |
115/208/230V |
36" |
- |
18" |
|
LPV42* |
115/208/230V |
42" |
- |
21" |
|
LPV48* |
115/208/230V |
48" |
- |
24" |
|
LPV60* |
115/208/230V |
60" |
13 1/4" |
30" |
|
LPV72* |
115/208/230V |
72" |
17" |
36" |
Units Length 84" and above, use two Mounting
Brackets with 2" in between |
|
LPV84-2* |
115/208/230V |
86" |
- |
21" (2) |
|
LPV96-2* |
115/208/230V |
98" |
- |
24" (2) |
|
LPV108-2* |
115/208/230V |
110" |
Use LPV48
and 60 brackets |
|
LPV120-2* |
115/208/230V |
122" |
13 1/4" (2) |
30" (2) |
|
LPV144-2* |
115/208/230V |
146" |
17" (2) |
36" (2) |
|
|
|
 |
|
|
*
- Unit also available for LPN series |
|
|
|
|
|
|
MAINTENANCE
INSTRUCTION
|
|
|
|
|
| ROUTINE
MAINTENANCE |
WARMING
- TO REDUCE THE RISK OF FIRE,
ELECTRICAL SHOCK OR INJURY TO PERSONS,
OBSERVE THE FOLLOWING: |
|
It
is imperative to keep the fans clean, as they eventually
become coated with residue. Dirty fans will lower the
efficiency and eventually throw fans out of balance which
can shorten the life of the blower wheels and cause undue
wear on the bearings. The time between cleanings depend
upon the type and amount of particles floating in the air.
Under normal circumstances, the system will require
cleaning only about once a year. |
|
Use
this unit only in the manner intended by the
manufacturer, if you have any questions, contact the
manufacturer. Before servicing or cleaning the unit,
switch power off at service panel and lock to prevent
power from being switched on accidentally. Servicing
an energized air curtain presents a risk of fire, electric
shock or injury to persons. DO NOT attempt any
maintenance unless the electric supply has been
completely disconnected. Installation work with all
electrical wiring must be done by qualified person(s) in
accordance with all applicable codes and standards.
When cutting or drilling into wall or ceiling, do not
damage electrical wiring and other hidden utilities. |
|
|
|
TO
KEEP THE LoPro AIR CURTAIN LOOKING
NEW, REMOVE SCREWS FROM AIR INTAKE
OPENING AND REMOVE AIR INTAKE GRILLE.
CLEAN ACCUMULATION OF DIRT FROM
MOTOR HOUSING, BLOWER WHEELS &
INTAKE GRILLE THEN REINSTALL INTAKE
GRILLE. |
|
|
|
 |
|
 |
|
Commercial Air
Curtains, Air Curtain, Air Curtain Door, Air Curtain Heater,
Air Curtains, Air Doors, Door Air Curtains, Heat Curtains,
Mars Air Curtain, Mars Air Door, Warm Air Curtains, and Insect
Barrier from your source for material handling equipment.
|
Back
to Product Category |
 |
|